Page #275 background image
For
HP
Internal Use Only
If
the
Non-Activity Timer is disabled
(OFF),
the Access
Port
firmware does not monitor the
console input for non-activity.
The
default setting for this feature is disabled
(OFF).
CMD_RESET Monitor. When
the
CMD_RESET Monitor is enabled (ON)
and
the Access
Port
firmware is in the CONTROL mode,
the
Access
Port
monitors the bus for RESET.
If
it
is
detected,
the
Access
Port
firmware exits
the
CONTROL mode
and
goes into the MONITOR
mode.
If
the
CMD_RESET Monitor is disabled
(OFF),
the
Access
Port
firmware ignores RESETs on
the
bus.
The
default setting for this feature is disabled
(OFF).
Restricted Command Set. When the Restricted Command Set is enabled (ON), only the HE,
CO, and
SO
commands can be executed. Use of any
other
command results in
the
error
message
Unknown Command.
All commands are available when the Restricted Command Set is disabled
(OFF).
The
default setting for this feature is disabled
(OFF).
TC:
Initiate Transfer
Of
Control
Definition:
This command initiates a system Transfer Of Control by asserting the
TOC
line connected
to
the
host's SPU through
the
support cable. After completion of this command, the AP is
placed in console mode in preparation for rebooting
the
system.
Valid From: Local Console
Port,
Remote Modem
Port
TA:
Initiate lAP Self-Test
Definition:
This command causes
the
lAP
card
to
execute
its
self-test. Execution of the self-test does not
alter the configuration or disconnect the modem
port
if
on line. However, any
data
sent
to
the
I/0
card during self-test will be lost.
Valid From: Local Console
Port,
Remote Modem
Port
TE: Tell
Definition:
This command
treats
all displayable characters following the
TE
command as a comment.
Since characters are echoed
to
the local console terminal and
to
the remote console terminal if
it
is connected, this has
the
effect of sending a message
to
the
other
terminal. The comment
string, including
the
command mnemonic, is limited
to
a maximum of
80
characters.
Valid From: Local Console
Port,
Remote Modem
Port
UR:
Unlock Remote Support Modem Access
Definition:
9-12 Functional Description

Table of Contents