EasyManuals Logo

HP Carrier-Grade rx2800 i2 Server DC User Manual

HP Carrier-Grade rx2800 i2 Server DC
149 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #130 background imageLoading...
Page #130 background image
A Utilities
SAS disk setup
Using the saupdate command
The saupdate command is used to query or change the mode of the Smart Array P410i and
Smart Array P411 controllers to HBA or RAID. Querying or changing modes is not supported for
other controllers.
The newly added commands to saupdate are:
Get Mode
Set Mode
Get mode
This command displays the current mode of the controllers.
Syntax
saupdate get_mode <controller>
<controller> can be any one of the following strings.
Table 41 <controller> strings
Meaning<controller>
A controller having the PCI segment id, bus id, device id and function id is addressed<seg:bus:dev:func>
Addresses all controllers in the systemall
Controllers of a particular type indicated by the <model> string are addressed<model>
130 Utilities

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Carrier-Grade rx2800 i2 Server DC and is the answer not in the manual?

HP Carrier-Grade rx2800 i2 Server DC Specifications

General IconGeneral
Form Factor2U Rack
Product TypeCarrier-grade server
Memory TypeDDR3
Hard Drive InterfaceSAS
StorageUp to 8x 2.5-inch SAS HDDs/SSDs
Power SupplyRedundant Power Supplies
Operating SystemHP-UX
Operating System SupportHP-UX
ProcessorIntel Itanium Processor 9300 series
MemoryUp to 384 GB (24 DIMM slots)

Related product manuals