EasyManua.ls Logo

HP DL360

HP DL360
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting 161
Adapter/NVRAM ID Mismatch
Description: EISA NVRAM has an ID for a different controller from the one
physically present in the slot.
Action: Run the server setup utility.
Array Accelerator Battery Pack X not Fully Charged
Description: Battery is not fully charged.
Action: If 75% of the batteries present are fully charged, the array accelerator is
fully operational. If more than 75% of the batteries are not fully charged, allow
36 hours to recharge them.
Array Accelerator Battery Pack X Below Reference Voltage (Recharging)
Description: Battery pack on the array accelerator is below the required voltage
levels.
Action: Replace the array accelerator board if the batteries do not recharge
within 36 powered-on hours.
Board in Use by Expand Operation
Description: Array accelerator memory is in use by an expand operation.
Action: Operate the system without the array accelerator board until the expand
operation completes.
Board not Attached
Description: An array controller is configured for use with array accelerator
board, but one is not connected.
Action: Connect array accelerator board to array controller.

Table of Contents

Other manuals for HP DL360

Related product manuals