Controller Communication Failure Occurred
Description: Controller communication failure occurred. ADU was unable to
successfully issue commands to the controller in this slot.
Action:
1. Be sure all cables are properly connected and working.
2. Be sure the controller is working, and replace if needed.
Controller Detected. NVRAM Configuration not Present
Description: EISA NVRAM does not contain a configuration for this controller.
Action: Run the server setup utility to configure the NVRAM.
Controller Firmware Needs Upgrading
Description: Controller firmware is below the latest recommended version.
Action: Run Options ROMPaq to upgrade the controller to the latest firmware
revision.
Controller is Located in Special "Video" Slot
Description: Controller is installed in the slot for special video control signals. If
the controller is used in this slot, LED indicators on front panel may not function
properly.
Action: Install the controller into a different slot, and run the server setup utility
to configure NVRAM. Then, run ACU to configure the controller.

Table of Contents

Other manuals for HP DL360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP DL360 and is the answer not in the manual?

HP DL360 Specifications

General IconGeneral
Processor Sockets2
CPUIntel Xeon Scalable
MemoryUp to 3TB DDR4
Form Factor1U Rack
Power SupplyRedundant Power Supplies, various wattage options
Network ControllerEmbedded 1Gb or 10Gb Ethernet
RAID SupportSmart Array RAID
Operating System SupportWindows Server, Linux, VMware
StorageUp to 10 SFF SAS/SATA/NVMe drives or 4 LFF SAS/SATA drives

Related product manuals