214 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
1611- Power Supply Zone Fan Assembly Failure Detected. Either...
...the Assembly is not installed or multiple fans have failed.
Audible Beeps: None
Possible Cause: Required fans are missing or not spinning.
Action:
1. Check the fans to be sure they are installed and working.
2. Be sure the assembly is properly connected and each fan is properly seated.
3. If the problem persists, replace the failed fans.
4. If a known working replacement fan is not spinning, replace the assembly.
1611-Power Supply Zone Fan Assembly Failure Detected. Single
fan...
...failure. Assembly will provide adequate cooling.
Audible Beeps: None
Possible Cause: Required fan not spinning.
Action: Replace the failed fan to provide redundancy, if applicable.
1611-Primary Fan Failure (Fan Zone System)
Audible Beeps: None
Possible Cause: A required fan is not spinning.
Action: Replace the failed fan.

Table of Contents

Other manuals for HP DL360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP DL360 and is the answer not in the manual?

HP DL360 Specifications

General IconGeneral
Processor Sockets2
CPUIntel Xeon Scalable
MemoryUp to 3TB DDR4
Form Factor1U Rack
Power SupplyRedundant Power Supplies, various wattage options
Network ControllerEmbedded 1Gb or 10Gb Ethernet
RAID SupportSmart Array RAID
Operating System SupportWindows Server, Linux, VMware
StorageUp to 10 SFF SAS/SATA/NVMe drives or 4 LFF SAS/SATA drives

Related product manuals