EasyManuals Logo

HP DL360 Reference And Troubleshooting Guide

HP DL360
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #156 background imageLoading...
Page #156 background image
156 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
Attached Drives..........................................................................................................................181
Swapped Cables or Configuration Error Detected. The Maximum Logical Volume Count X...182
System Board is Unable to Identify which Slots the Controllers are in .....................................182
This Controller Can See the Drives but the Other Controller Can't ...........................................183
The Redundant Controllers Installed are not the Same Model...................................................183
This Controller Can't See the Drives but the Other Controller Can ...........................................183
Unable to Communicate with Drive on SCSI Port X, Drive ID Y.............................................183
Unable to Retrieve Identify Controller Data. Controller May be Disabled or Failed.................184
Unknown Disable Code..............................................................................................................184
Unrecoverable Read Error..........................................................................................................184
Warning Bit Detected .................................................................................................................184
WARNING - Drive Write Cache is Enabled on X.....................................................................185
WARNING: Storage Enclosure on SCSI Bus X Indicated it is Operating in Single Ended
Mode...........................................................................................................................................185
Write Memory Error...................................................................................................................185
Wrong Accelerator .....................................................................................................................186
Introduction to ADU Error Messages
This section contains a complete alphabetical list of all ADU ("Array Diagnostic
Utility" on page 80
) error messages.
IMPORTANT: This guide provides information for multiple servers.
Some information may not apply to the server you are troubleshooting.
Refer to the server documentation for information on procedures,
hardware options, software tools, and operating systems supported by
the server.
WARNING: To avoid potential problems, ALWAYS read
the warnings and cautionary information in the server
documentation before removing, replacing, reseating, or modifying
system components.
Accelerator Board not Detected
Description: Array controller did not detect a configured array accelerator board.
Action: Install an array accelerator board on an array controller. If an array
accelerator board is installed, check for proper seating on the array controller
board.

Table of Contents

Other manuals for HP DL360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP DL360 and is the answer not in the manual?

HP DL360 Specifications

General IconGeneral
Processor Sockets2
CPUIntel Xeon Scalable
MemoryUp to 3TB DDR4
Form Factor1U Rack
Power SupplyRedundant Power Supplies, various wattage options
Network ControllerEmbedded 1Gb or 10Gb Ethernet
RAID SupportSmart Array RAID
Operating System SupportWindows Server, Linux, VMware
StorageUp to 10 SFF SAS/SATA/NVMe drives or 4 LFF SAS/SATA drives