EasyManua.ls Logo

HP DL360

HP DL360
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
194 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
2. Be sure no keys are depressed or stuck.
3. If the failure reoccurs, replace the keyboard.
Parity Check 2 - System DIMM Memory
Audible Beeps: None
Possible Cause: An uncorrectable error memory event occurred in a memory
DIMM.
Action: Run Insight Diagnostics to identify failed DIMMs. Then, identify failed
DIMMs with LEDs and replace the DIMMs.
PCI Bus Parity Error, PCI Slot x
Audible Beeps: None
Possible Cause: A PCI device has generated a parity error on the PCI bus.
Action: For plug-in PCI cards, remove the card. For embedded PCI devices, run
Insight Diagnostics and replace any failed components as indicated.
Power Fault Detected in Hot-Plug PCI Slot x
Audible Beeps: 2 short
Possible Cause: PCI-X Hot Plug expansion slot was not powered up properly.
Action: Reboot the server.
Redundant ROM Detected - This system contains a valid backup
system ROM.
Audible Beeps: None
Possible Cause: The system recognizes both the system ROM and redundant
ROM as valid. This is not an error.
Action: None

Table of Contents

Other manuals for HP DL360

Related product manuals