EasyManuals Logo

HP DL360 Reference And Troubleshooting Guide

HP DL360
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #185 background imageLoading...
Page #185 background image
Troubleshooting 185
WARNING - Drive Write Cache is Enabled on X
Description: Drive has its internal write cache enabled. The drive may be a
third-party drive, or the operating parameters of the drive may have been altered.
Condition can cause data corruption if power to the drive is interrupted.
Action: Replace the drive with a supported drive or restore the operating
parameter of the drive.
WARNING: Storage Enclosure on SCSI Bus X Indicated it is Operating in Single
Ended Mode...
...SOLUTION: This usually occurs when a single-ended drive type is inserted into an
enclosure with other drive types; and that makes the entire enclosure operate in single
ended mode. To maximize performance replace the single-ended drive with a type that
matches the other drives.
Description: One or more single-ended mode SCSI drives are installed in an
external storage unit that operates in LVD mode.
Action: The array continues to operate, but installing all LVD drives maximizes
performance.
Write Memory Error
Description: Data cannot be written to the cache memory. This typically means
that a parity error was detected while writing data to the cache. This can be
caused by an incomplete connection between the cache and the controller. This is
not a data loss circumstance.
Action: Power down the system and be sure that the cache board is fully
connected to the controller.

Table of Contents

Other manuals for HP DL360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP DL360 and is the answer not in the manual?

HP DL360 Specifications

General IconGeneral
Processor Sockets2
CPUIntel Xeon Scalable
MemoryUp to 3TB DDR4
Form Factor1U Rack
Power SupplyRedundant Power Supplies, various wattage options
Network ControllerEmbedded 1Gb or 10Gb Ethernet
RAID SupportSmart Array RAID
Operating System SupportWindows Server, Linux, VMware
StorageUp to 10 SFF SAS/SATA/NVMe drives or 4 LFF SAS/SATA drives