Troubleshooting 191
FATAL ROM ERROR: The System ROM is not Properly Programmed.
Audible Beeps: 1 long, 1 short
Possible Cause: The System ROM is not properly programmed.
Action: Replace the physical ROM part.
High Temperature Condition detected by Processor x
Audible Beeps:
Possible Cause: Ambient temperature exceeds recommended levels, fan solution
insufficient, or fans have failed.
Action: Adjust ambient temperature, install fans, or replace failed fans.
Illegal Opcode - System Halted
Audible Beeps: None
Possible Cause: The server has entered the Illegal Operator Handler because of
an unexpected event. This error is often software-related and does not necessarily
indicate a hardware issue.
Action: Run Insight Diagnostics and replace any failed components as indicated.
Be sure that all software is installed properly.
iLO Generated NMI
Audible Beeps: None
Possible Cause: The iLO controller generated an NMI.
Action: Check the iLO logs for details of the event.