EasyManua.ls Logo

HP Jet Fusion 5200 Series - Page 303

HP Jet Fusion 5200 Series
392 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. Remove the filter.
Finish replacement
The following steps provide the complete procedure for this topic.
1. Install the new filter. Notice that the arrow should appear in the upper part of the filter.
2. Place the cover.
3. Put back the 4 screws.
4. Reset the filter after installation. Go to front panel > Settings > Utilities > Maintenance > Replace
parts > Reset e-box fan filter counter.
Safety maintenance of the processing station
Check the functionality of the Residual Current Circuit Breaker (RCCB)
Following standard RCCB recommendations, it is recommended that the RCCB is tested on a yearly
basis. T
he procedure is as follows:
1. Turn off the processing station from the front panel, not using the service switch.
296 Chapter 11 Hardware maintenance