Solution: move the parts slightly off one from the other so that their edges are not exactly aligned, as
sho
wn (the same would be done for the other two groups not highlighted).
Detailing agent has a group of clogged nozzles in that area
Check the printheads Health Gauge through the Front Panel. If the Health Gauge shows “Printhead is
per
forming as expected”, run a User Recovery routine and check the Health Gauge again.
Solution: Health Gauge reads “Printhead is underperforming. Part quality will be affected”: replace the
affected printhead(s).
The printhead caps are wrongly assembled and they touch the nozzle plate of one of the
prin
theads
This topic describes what to do if the printhead caps are wrongly assembled and they touch the nozzle
plat
e of one of the printheads.
Detailing agent has a group of clogged nozzles in that area 347