HP ProLiant server errors 97
System Fans Not Redundant
Event Type: Fans not redundant
Action: Add a fan or replace the failed fan.
System Overheating (Zone X, Location)
Event Type: Overheating condition
Action: Check fans.
System Power Supplies Not Redundant
Event Type: Power supply not redundant
Action: Add a power supply or replace the failed power supply.
System Power Supply Failure (Power Supply X)
Event Type: Power supply failure
Action: Replace the power supply.
Unrecoverable Host Bus Data Parity Error...
...Unrecoverable Host Bus Address Parity Error
Event Type: Host bus error
CAUTION: Only authorized technicians trained by HP should attempt to remove the system
board. If you believe the system board requires replacement, contact HP Technical Support ("HP
contact information" on page 399) before proceeding.
Action: Replace the board on which the processor is installed.
Uncorrectable Memory Error (Slot X, Memory Module Y)...
...Uncorrectable Memory Error (System Memory)
Uncorrectable Memory Error (Memory Module Unknown)
Event Type: Uncorrectable error
Action: Replace the memory module. If the problem persists, replace the memory board.
Windows® Event Log processor error codes
Message ID: 4137
Severity: Error
Description: The processor in slot X, socket X has corrected an excessive number of internal errors. The system