EasyManua.ls Logo

HP ProLiant Gen9 - Message Identifiers 24775-24799

HP ProLiant Gen9
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HP Smart Array errors 149
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis number> has reported that a tape drive has been <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24774
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting <link up / down> for PHY number <PHY number>.
This PHY link status change has occurred on port <port number> of the external
array controller.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message identifiers 24775-24799
Message Id: 24775
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that the <drive type> physical hard drive located
in bay <bay number> is offline. The offline reason received from the HP Smart
Array firmware is: <firmware error code>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
<firmware error code> values:
TOO_SMALL_IN_LOAD_CONFIG - Replacement drive is too small for configured
volume(s).
ERROR_ERASING_RIS - Could not write to reserved configuration sectors after
multiple retries.
ERROR_SAVING_RIS - Could not write to reserved configuration sectors after
multiple retries.
FAIL_DRIVE_COMMAND - “Fail Drive” command received from host.
MARK_BAD_FAILED - Unable to create media defect after multiple retries.
MARK_BAD_FAILED_IN_FINISH_REMAP - Unable to create media defect after
multiple retries.
TIMEOUT - Too many SCSI command timeouts.
AUTOSENSE_FAILED - Drive is failing commands but is not returning SCSI sense
data after multiple retries.
MEDIUM_ERROR_1 - Caused by a particular set of SCSI sense codes that indicate
the drive is in bad shape and its data may be corrupt.
MEDIUM_ERROR_2 - Caused by a particular set of SCSI sense codes that indicate
the drive is in bad shape; retries did not help.
NOT_READY_BAD_SENSE - Drive is returning unrecognized Not Ready sense codes.

Table of Contents

Related product manuals