HP ProLiant server errors 51
163-Time & Date Not Set
Possible Cause: Invalid time or date in configuration memory.
Action: Run the server setup utility and correct the time or date.
172-1-Configuration Non-volatile Memory Invalid
Audible Beeps: None
Possible Cause: Nonvolatile configuration corrupted.
Action: Run the server setup utility and correct the configuration.
180-Log Reinitialized
Audible Beeps: None
Possible Cause: The IML has been reinitialized due to corruption of the log.
Action: Event message, no action is required.
200 Series
201-Memory Error
Audible Beeps: None
Possible Cause: Memory failure detected.
Action: Run Insight Diagnostics and replace failed components as indicated.
203-Memory Address Error
Audible Beeps: None
Possible Cause: Memory failure detected.
Action: Run Insight Diagnostics and replace failed components as indicated.
207 - Invalid Memory Configuration Detected. DIMMs installed when no
corresponding processor is detected.
Description: Processor is required to be installed for memory to be used.
Action:
CAUTION: Before removing or replacing any processors, be sure to follow the guidelines
provided in "Performing processor procedures in the troubleshooting process" provided in the HP
ProLiant Gen9 Troubleshooting Guide: Volume 1, Troubleshooting. Failure to follow the
recommended guidelines can cause damage to the system board, requiring replacement of the
system board.
Populate the processor socket or remove the DIMM.