Message Id: 24699
Severity: Warning
Log message: A SAS link error has been detected between a switch expander and I/O
module <module number> of box <box number>. This hardware is connected to port
<port number> of controller <controller name / slot information>. Please check
this data path and the associated hardware.
Message identifiers 24700-24724
Message Id: 24700
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that a <drive type> physical hard drive in bay
<bay number> was <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24701
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan number <fan number> has failed. The
external Smart Array controller may attempt to shut down power and/or spin down
the installed disk drive(s).
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24702
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan number <fan number> is reporting a
degraded condition.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24703
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan number <fan number> is now operational.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24704
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is indicating that sensor number <sensor number> has reported
that the internal temperature has exceeded the preset temperature limit. The
external Smart Array controller may attempt to shut down power to and/or spin
down the installed disk drive(s).