EasyManua.ls Logo

HP Xw9400 - Workstation - 16 GB RAM - Page 175

HP Xw9400 - Workstation - 16 GB RAM
221 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Screen Message Probable Cause Recommended Action
915–Fan Power from
Power Supply Not
Connected
The fan power cable is not
connected, or the power
supply is bad.
CAUTION: Disconnect AC power from the
workstation before reseating or replacing
components because there is power to the
system board even when the workstation is
powered down.
1. Verify that all power supply cables are
connected.
2. Replace the power supply.
916–Power Button Not
Connected
The power button is not
connected.
CAUTION: Disconnect AC power from the
workstation before reseating or replacing
components because there is power to the
system board even when the workstation is
powered down.
Connect the power button.
917–Front Audio Not
Connected
The front audio cable is not
connected.
CAUTION: Disconnect AC power from the
workstation before reseating or replacing
components because there is power to the
system board even when the workstation is
powered down.
Connect the front audio cable.
918–Front USB Not
Connected
Front USB is not connected. CAUTION: Disconnect AC power from the
workstation before reseating or replacing
components because there is power to the
system board even when the workstation is
powered down.
Connect the front USB cable.
921–Device in PCI
Express Slot Failed to
Initialize
A PCI Express card was
detected in one of the slots, but
failed to initialize properly.
CAUTION: Disconnect AC power from the
workstation before reseating or replacing
components because there is power to the
system board even when the workstation is
powered down.
Reseat all PCI Express cards. If this failure
occurred after inserting a new card, there
could be a problem with that card.
922–Fatal error on slot # Fatal error occurred in the
designated slot.
CAUTION: Disconnect AC power from the
workstation before reseating or replacing
components because there is power to the
system board even when the workstation is
powered down.
Try moving card to a different slot. If the
problem persists, try replacing the card.
923–Non fatal error on
slot #
A PCI or PCIe non-fatal error
condition occurred for the
device in the designated slot.
CAUTION: Disconnect AC power from the
workstation before reseating or replacing
components because there is power to the
system board even when the workstation is
powered down.
1. Reseat the card.
2. Try moving card to a different slot.
3. If the problem persists, replace the card.
Table 6-18 POST error messages (continued)
ENWW POST error messages 165

Table of Contents

Other manuals for HP Xw9400 - Workstation - 16 GB RAM

Related product manuals