Component identification 7
Front panel LEDs and buttons
Item
Description
Status
1
Health LED
Solid green = Normal
Flashing green (1 flash per second) = iLO is rebooting
Flashing amber = System degraded
Flashing red (1 flash per second) = System critical
If the health LED indicates a degraded or critical state, review the system IML
("Integrated Management Log" on page 58) or use iLO ("HPE iLO" on page
57) to review the system health status.
2
Power On/Standby
button and system
power LED
Solid green = System on
Flashing green (1 flash per second) = Performing power on sequence
Solid amber = System in standby
Off = No power present
Facility power is not present, power cord is not attached, no power supplies
are installed, power supply failure has occurred, or the front I/O cable is
disconnected.
3
UID LED
Solid blue = Activated
Flashing blue:
1 flash per second = Remote management or firmware upgrade in
progress
4 flashes per second = iLO manual reboot sequence initiated
8 flashes per second = iLO manual reboot sequence in progress
Off = Deactivated
4
NIC status LED
Solid green = Link to network
Flashing green (1 flash per second) = Network active
Off = No network activity
When all four LEDs described in this table flash simultaneously, a power fault has occurred. For more information,
see "Front panel LED power fault codes (on page 7)."
Front panel LED power fault codes
The following table provides a list of power fault codes, and the subsystems that are affected. Not all
power faults are used by all server blades.