8. Cable the controller.
9. To enable HPE Smart Array SR SmartCache in a Smart Array P-class Gen10 controller, install the energy pack.
SmartCache and CacheCade enable solid-state drives to be used as caching devices for hard drive media. These
features accelerate access to frequently used data by caching hot data from the hard drives onto the solid-state
drives.
10.
Install the access panel.
11.
Install the server into the rack.
12.
Connect all peripheral cables to the server.
13.
Connect each power cord to the server.
14.
Connect each power cord to the power source.
15.
Power up the server.
16.
Configure the storage controller.
The installation is complete.
Installing a Smart Array PCIe plug-in controller
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
Smart Array PCIe plug-in controller option
Compatible controller cable option
T-15 Torx screwdriver
If you are installing a Smart Array P-class Gen10 controller,
an energy pack option is required.
Before you perform this procedure, perform the following steps:
1. Back up data on the system.
2. Close all applications.
Hardware options installation 63