Installing an energy pack
Prerequisites
Before you perform this procedure:
Make sure that a Smart Array P-class controller is installed.
Make sure that you have the following items available:
Storage controller backup power cable (ships with the storage controller)
Energy pack option
If you are installing the HPE Smart Storage Hybrid Capacitor, verify that the server meets the minimum firmware
version for the capacitor pack installation.
Procedure
1.
Power down the server.
2. Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Disconnect all peripheral cables from the server.
4.
Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
5.
Remove the access panel.
6.
Install the energy pack.
7. Connect the controller backup power cable.