Fan option
Fan population
The number of fans installed in the server determines fan redundancy.
Configuration Bay 1 Bay 2 Bay 3 Bay 4 Bay 5 Bay 6 Bay 7
4LFF
1
Blank Fan Fan Fan Fan Fan Blank
8SFF SAS or SATA
1
Blank Fan Fan Fan Fan Fan Blank
4LFF or 8SFF with a
GPU installed
Blank Fan Fan Fan Fan Fan Fan
8SFF NVMe
1
Fan Fan Fan Fan Fan Fan Fan
1
This configuration supports fan redundancy.
Fan mode behavior
In nonredundant fan mode, a fan failure or a missing fan causes:
The system Health LED to flash amber.
The operating system to orderly shutdown.
In redundant fan mode:
A fan rotor failure will switch the system to nonredundant fan mode.
This change is indicated by the Health LED flashing amber. The system continues to operate normally in this
mode.
A second fan rotor failure or a missing fan causes the operating system to orderly shutdown.
Installing a fan
This server supports redundant fans to provide suicient airflow to the system if a fan rotor fails.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are
populated with either a component or a blank.
Procedure
1. Power down the server.
2. Remove all power:
Hardware options installation 79