EasyManua.ls Logo

HPE ProLiant DL380 Gen10 - Installing a Front 8 SFF SAS;SATA Drive Cage in Box 1

HPE ProLiant DL380 Gen10
201 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing a front 8SFF SAS/SATA drive cage in box 1
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
T-10 Torx screwdriver
The components included with the hardware option kit
Procedure
1.
Power down the server.
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
4.
Remove the access panel.
5. Remove the air bale.
6. Remove the fan cage.
7. Remove the bay blank.
Hardware options installation