NOTE:
• Any RAID configuration created for the HPE Smart Array MR controller is not available to HPE Smart Array SR controllers.
• The message "Data Protection disabled" in the logical drive properties can be ignored as it refers to a feature not currently
supported by the HPE MR Storage Administrator product.
Installing a Universal Media Bay
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
• The components included with the hardware option kit
• T-10 Torx screwdriver
Procedure
1.
Power down the server.
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
•
Extend the server from the rack.
• Remove the server from the rack.
4.
Remove the access panel.
5.
Remove the air bale.
6.
Remove the fan cage.
7.
Remove the bay blank.
Hardware options installation
96