Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
•
Extend the server from the rack.
• Remove the server from the rack.
4. Remove the access panel.
5.
Remove the riser cage.
6. Install the drive.
The installation is complete.
Fan options
CAUTION: To avoid damage to server components, fan blanks must be installed in fan bays 1 and 2 in a single-
processor configuration.
CAUTION: To avoid damage to the equipment, do not operate the server for extended periods of time if the server does
not have the optimal number of fans installed. Although the server might boot, Hewlett Packard Enterprise does not
recommend operating the server without the required fans installed and operating.
Valid fan configurations are listed in the following table.