IMPORTANT: For optimum cooling, install fans in all primary fan locations.
Removing the air bale or midplane drive cage
CAUTION: Do not detach the cable that connects the battery pack to the cache module. Detaching the cable causes any
unsaved data in the cache module to be lost.
CAUTION: For proper cooling, do not operate the server without the access panel, bales, expansion slot covers, or
blanks installed. If the server supports hot-plug components, minimize the amount of time the access panel is open.
Procedure
1.
Power down the server.
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
•
Extend the server from the rack.
•
Remove the server from the rack.
4. Remove the access panel.
5. Do one of the following:
• Remove the air
bale.
Operations
53