9. Install the 12G SAS expander card.
IMPORTANT: The 12G SAS expander card requires a controller. The server supports embedded, type-a, and type-
p Smart Array controllers. If using a type-p Smart Array controller, then install the controller in slot 1.
10. Using the labels on each cable, connect the cables to the SAS expander.
For drive numbering, see "Drive bay numbering: SAS expander".
11. Install the riser cage.
12. Connect cables from the 12G SAS expander to the controller.
13.
Connect cables from the 12G SAS expander to the drive backplanes.
A standard configuration is shown. For additional cabling diagrams, see
Cabling diagrams.
14. Install the fan cage.
15.
Install the air bale.
Hardware options installation