Shenzhen Hpmont Technology Co., Ltd Appendix A Parameters
HD30 Series Inverters User Manual 131
No. Name Range
Factory
Default
Unit
Modified
attributes
Setting
1: Acc./Dec. time 2
2: Acc./Dec. time 3
3: Acc./Dec. time 4
F06.18 Running time of step 1 0.03276.7 5.0 0.1
F06.20 Running time of step 2 0.03276.7 0.0 0.1
F06.22 Running time of step 3 0.03276.7 0.0 0.1
F06.24 Running time of step 4 0.03276.7 0.0 0.1
F06.26 Running time of step 5 0.03276.7 0.0 0.1
F06.28 Running time of step 6 0.03276.7 0.0 0.1
F06.30 Running time of step 7 0.03276.7 0.0 0.1
F06.32 Running time of step 8 0.03276.7 0.0 0.1
F06.34 Running time of step 9 0.03276.7 0.0 0.1
F06.36
Running time of step
10
0.03276.7
0.0 0.1
F06.38 Running time of step 11 0.03276.7 0.0 0.1
F06.40
Running time of step
12
0.03276.7
0.0 0.1
F06.42
Running time of step
13
0.03276.7
0.0 0.1
F06.44
Running time of step
14
0.03276.7
0.0 0.1
F06.46
Running time of step
15
0.03276.7
0.0 0.1
Group F07 Wobble Operation Parameters (refer to pages 71
73)
F07.00
Wobble operation
selection
0: Disabled
1: Enabled
0 1 ×
F07.01
Wobble operation
mode
Units: Start mode of wobble
operation
0: Auto start (according to
F07.03)
1: Manual start
Tens: Wobble operation
amplitude
0: Relative to the wobble
central frequency
1: Relative to the maximum
output frequency
Hundreds: Restart mode of
wobble operation
0: The inverter restarts the
wobble operation as per the
recorded frequency and
direction when it stops last
0000 1 ×