Shenzhen Hpmont Technology Co., Ltd Chapter 6 Function Introduction
HD30 Series Inverters User Manual 65
No. Name Description Range
factory setting
F04.18 PID output reverse selection 0,1
0
0: PID regulation disable reverse. When PID output is negative, 0 is the limit.
1: PID regulation enable reverse. When F00.18 = 1 (disable reverse), 0 is the limit.
F04.19 PID output reverse frequency’s upper limit 0.00
upper limit
50.00Hz
It defines the PID upper limit frequency when reverse. When F04.18 = 1 (PID regulation enable
reverse), it is enabled.
6.2.6 Group F05 External Reference Curve Parameters
No. Name Description Range
factory setting
F05.00
External reference curve selection
000002222200000
Units: AI1 characteristic curve selection.
Tens: AI2 characteristic curve selection.
Hundreds: AI3 characteristic curve selection.
Thousands: AI4 characteristic curve selection.
Ten thousands: Pulse input characteristic curve selection.
Each bit setting:
0: Line 1.
1: Line 2.
2: Polyline.
Note: Only when using HD30-EIO can hundreds and thousands be enabled.
F05.01
Minimum reference of line 1
0.0F05.030.0%
F05.02 Minimum reference corresponding value of line 1 0.0
100.0%
0.0
F05.03
Maximum reference of line 1
F05.01100.0%100.0%
F05.04 Maximum reference corresponding value of line 1 0.0
100.0%
100.0
F05.05
Minimum reference of line 2
0.0F05.070.0%
F05.06 Minimum reference corresponding value of line 2 0.0
100.0%
0.0
F05.07
Maximum reference of line 2
F05.05100.0%100.0%
F05.08 Maximum reference corresponding value of line 2 0.0
100.0%
100.0
F05.09
Maximum reference of polyline
F05.11100.0%100.0%
F05.10 Maximum reference corresponding value of polyline 0.0
100.0%
100.0
F05.11
Inflection point 2 reference of polyline
F05.13F05.09100.0%
F05.12 Inflection point 2 corresponding value 0.0
100.0%
100.0
F05.13
Inflection point 1 reference of polyline
F05.15F05.110.0%
F05.14 Inflection point 1 corresponding value 0.0
100.0%
0.0
F05.15
Minimum reference of polyline
0.0F05.130.0%
F05.16 Minimum reference corresponding value of polyline 0.0
100.0%
0.0
F05.01F05.04 define the line 1. F05.05F05.08 define the line 2. F05.09F05.16 define the
polyline.
Line 1, line 2 and polyline can independently achieve positive and negative characteristics as
shown in following figure.
If set the curve’s minimum reference the same as maximum reference, it must be a line. The
default frequency is the corresponding frequency of the curve minimum reference.
6

Table of Contents

Other manuals for hpmont HD30 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the hpmont HD30 Series and is the answer not in the manual?

hpmont HD30 Series Specifications

General IconGeneral
Brandhpmont
ModelHD30 Series
CategoryInverter
LanguageEnglish

Related product manuals