Shenzhen Hpmont Technology Co., Ltd Appendix A Parameters
HD30 Series Inverters User Manual -139-
No. Name Range
Factory
Default
Unit
Modified
attributes
Setting
F15.08
DI9 terminal (option
terminal) function
selection
34: Holding PID integral
35: Clearing PID integral
36: Switch to wobble
operation
37: Reset the wobble
operating status
38: DC braking start while
stopping
39: External pause signal
(normally-open input)
40: External pause signal
(normally-closed input)
41: Coast to stop
(normally-open input)
42: Coast to stop
(normally-closed input)
43: Emergency stop
44: External fault signal
(normally-open input)
45: External fault signal
(normally-closed input)
46: External reset (RST)
input
47: Switch between motor 1
and motor 2
48: Timing function input
49: Clearing the length
50: Clearing the counter to
zero
51: Counter’s triggering
signal input
52: Length counting input
(only DI6 terminal is enabled)
53: Pulse frequency input
(only DI6 terminal is enabled)
0 1 ×
F15.09 Reserved
F15.10 Reserved
F15.11 Reserved
F15.12
Acc./Dec. rate of
UP/DN terminal
0.00-99.99Hz/s 1.00Hz/s
0.01Hz
/s
×
F15.13
Terminal detecting
interval
0: 2ms
1: 4ms
2: 8ms
1 1 ○
F15.14
Terminal detecting filter
number
0-100ms 10ms 1ms ○
F15.15
Terminal input positive
and negative logic
Bit0-Bit8 is corresponding
to DI1-DI9
000 1 ○
A