- 57 -
- „shidown point“
Species the force from which the seng speed is to be reduced.
Only available in the „rpm + force“ control mode.
„stop mode“ In the drop-down menu, it is possible to choose between „No stop“ for
switching between two steps and „ECO stop“ for the last step.
The parameter for rivet seng are dened in the „Strategy“ tab.
The individual funcons can be acvated by clicking on the On/O symbol. A green symbol
means acve, greyed out means inacve.
NBPS-21
stroke
„S
target
“ S
Target
describes the stroke that the tool should travel in this step. When
this value is reached, the tool changes to the next step.
„S
limit
“ S
Limit
describes the max. stroke the tool may cover in this step. When
this value is reached, the tool stops and displays an NOK error message.
current
„I
target
“ I
Target
describes the current that the tool should reach in this step. When
this value is reached, the tool changes to the next step.