- 56 -
The sengs for speed and pulling direcon are made in the „Gear“ tab.
„stroke“ The direcon of the stroke is parametrised here. The default is „Pulling
direcon“. The „Start posion“ seng is only required for special ap-
plicaons. If you have any quesons, please contact our support team:
support@hs-technik.com
„start-up ramp“ This me denes the ramp with which the motor moves to the target
speed, recommended value 0.1 - 0.2 seconds.
„control method“ Adjustment of the engine control. „Set rpm“ is the default seng. In the
„regulate rpm“ control mode, the tool keeps the speed constant even
under load.
- „regulate rpm“
The speed control corresponds to a closed control loop. The tool will
try to maintain the set speed even under load.
- „set rpm“
The speed control corresponds to an open control loop. The tool will
not readjust the speed under load.
- „rpm + force“
The speed control is dependent on the measured force. Only possible
when F
Target
(NBPF-25) is acvated
- „seng speed
Target
“
Adjustment of the seng speed in %. Recommended seng for
screwing-on, level 1, 50 %, for seng, level 2, 80 - 100 %.
- „seng speed
min
“
Adjustment of the minimum seng speed