Display and Communication
Technical
Specications
SUN2000-20K
TL-M3
SUN2000-29.
9KTL-M3
SUN2000-30K
TL-M3
SUN2000-36K
TL-M3
SUN2000-40K
TL-M3
Display LED indicator; WLAN+app
RS485 Supported
Built-in WLAN Supported
AC MBUS
[1]
Supported
DC MBUS Supported
AFCI Supported
PID Supported
Note [1]: Inverters manufactured after July 20, 2022 do not support the AC MBUS.
General Specications
Technical
Specications
SUN2000-20K
TL-M3
SUN2000-29.
9KTL-M3
SUN2000-30K
TL-M3
SUN2000-36K
TL-M3
SUN2000-40K
TL-M3
Dimensions
(W x H x D)
640 mm x 530 mm x 270 mm
Net Weight 43 kg
Operating
temperature
–25°C to +60°C (derated when the temperature is above +45°C)
Humidity 0%–100%
Cooling mode Natural cooling
Maximum
operating
altitude
0–4000 m
Storage
temperature
–40°C to +70°C
IP rating IP66
Topology Transformerless
SUN2000-(20KTL, 29.9KTL, 30KTL, 36KTL, 40KTL)-
M3
User Manual 10 Technical Specications
Issue 11 (2023-01-10) Copyright © Huawei Technologies Co., Ltd. 91

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-M3 and is the answer not in the manual?

Huawei SUN2000-M3 Specifications

General IconGeneral
TypeString Inverter
Rated AC Grid Frequency50 Hz / 60 Hz
DC Connection TypeMC4
Protection DegreeIP65
Cooling MethodNatural convection
CategoryInverter
Adjustable Power Factor Range0.8 leading - 0.8 lagging
Total Harmonic Distortion (THD)≤ 3 %
Operating Temperature Range-25°C to 60°C
CommunicationRS485
Efficiency98%
Protection LevelDC reverse polarity protection, AC overcurrent protection, AC short-circuit protection, Overvoltage protection, Insulation monitoring, Residual current monitoring unit, Arc fault detection