Figure 2-34 Riser card 2 (one x8 slot and one x16 slot)
The riser card shown in Figure 2-35 is required for I/O module 1 or 2 in a
server with 8 x 2.5-inch SAS/SATA drives and 12 x 2.5-inch NVMe SSDs. Ports
A, B, and C are Slimline cable connectors.
Figure 2-35 Riser card 3 (dedicated for a server with 12 NVMe SSDs)
When congured with 2 x 2.5-inch rear drives respectively, both I/O modules
1 and 2 support x16 riser cards, as shown in Figure 2-36. This riser card
provides slot 3 when installed in I/O module 1, and slot 6 when installed in
I/O module 2.
TaiShan 200 Server
Maintenance and Service Guide (Model 2280) 2 Components
Issue 04 (2020-01-16) Copyright © Huawei Technologies Co., Ltd. 34

Table of Contents