Miscellaneous Pane
Figure 114. Miscellaneous Parameters Pane
Diagnosticsdetermines if the handset, headset, and/or the speaker are tested each time the diagnostic
self- test runs. Set this to HANDSET+HEADSET+SPEAKER to execute all diagnostics, any
combination of the three, or OFF.
Valid settings: OFF, HANDSET, HANDSET + HEADSET, SPEAKER, HANDSET + SPEAKER,
HEADSET + SPEAKER, HANDSET + HEADSET + SPEAKER.
LED Triggering Parameters
LED1LED5Configure each LED to turn on during various station conditions (see the I/O States
section).
Other
E-Z All Callonly valid on handset stations equipped with an ALL CALL paging pushbutton. This
parameter determines whether the handset pressbar must be pressed when making a page to the
PAGETX_B_SOCK multicast socket. Valid values are:
TRUEOnly the ALL CALL button needs to be pressed after lifting the handset to start paging to
the PAGETX_B_SOCK multicast address. The handset pressbar does not need to be pressed to
initiate the page. Pressing the handset pressbar without holding the ALL CALL button will initiate
a page on PAGETX_A_SOCK.
FALSEThe handset pressbar must always be pressed to make a page; including the use of the
ALL CALL button.
NOTE: Do not set this parameter to TRUE on stations that do not have an ALL CALL button.
Hookswitch Invert This parameter enables the inversion of the current physical state of the hook-
switch represented by the ON-HOOK and OFF_HOOK variables. Valid settings are:
TRUEON-HOOK and OFF-HOOK values are reversed.
FALSEON-HOOK and OFF-HOOK values are represent the actual current state of the
handset.
Handset Timeoutlimits the period that a station is off hook. This parameter is configured in minutes
with a default of eight minutes. A setting of zero disables the hookswitch timeout.
Pressbar Timeoutlimits the period that a page can continue. This parameter is configured in minutes
with a default timeout of two minutes. A setting of zero disables the pressbar timeout.

Table of Contents

Other manuals for Hubbell GAI-TRONICS E3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hubbell GAI-TRONICS E3 and is the answer not in the manual?

Hubbell GAI-TRONICS E3 Specifications

General IconGeneral
BrandHubbell
ModelGAI-TRONICS E3
CategoryController
LanguageEnglish

Related product manuals