If STATIC is selected, the reminders show up again at the end of the spin, and if in 
clip-on weight mode, the dynamic weights are shown momentarily, and then the 
static weight is displayed. 
3.16 Balancing Procedures for Specific Weight Types and 
Placement
Press   to change the weight types and placement. The GSP9720JLR offers 
Standard Balance, Mixed Weights Balance, Adhesive Weights Balance, and Patch 
Balance
£
 for dynamic and static modes. 
With these four selections, a correction weight can be placed at an infinite number of 
locations, based upon the choice of the operator. 
AUTO MODE DETECTION is the default setting automatically choosing the correct 
type of weights and locations determined by the placement of the Dataset® arms. 
STANDARD BALANCE should be selected when clip-on weights can be used for 
both rim flanges. 
MIXED WEIGHTS BALANCE should be selected when a clip-on weight can be used 
on the inner rim flange, but not on the outer rim flange. Mixed Weights Balance uses 
an adhesive weight for the right weight plane instead of a clip-on weight to avoid 
marring aluminum rims or to hide weights from view. 
ADHESIVE WEIGHTS BALANCE should be selected when clip-on weights cannot 
be used on either rim flange. 
GSP9720JLR Wheel Balancer Operation Instructions  Balancing Procedures 
 49