Safety equipment
6.9 Resistance test - stop function
Clean the contact areas and check resistance in
the following way:
Test the resistance by connecting a multimeter
as outlined in gure 16. NOTE! The power switch
must be in the “on” position to get the correct
reading. See gure 16.
The stop switch is in the “on” position when the
button is held down (see gure 16) and in the “off”
position when the button is in neutral.
Resistance can be 0.5 Ohm at most with the power
switch in the “on” position.
IMPORTANT! If the AutoTune connector is used, it
must be remounted in the mating connector after
use. See gure 17. Always start the chain saw after
service and conrm that the stop function is work-
ing.
6.8 Assembling the start/stop control
1
Fit the new stop control (A) and tighten screw (B)
in place with a torque of 1 Nm. Slide in the stop
control in the rubber sleeve C and hook the sleeve
on the guide taps. See gure 14.
Fig 14
Fig 16
Fig 15
2
Fit the cables as outlined in Figure 15.
3
Attach the air lter holder. See the “Assembling the
carburetor” chapter.
4
Assemble the air lter and cylinder cover.