English - 21
• Tilted X and Tilted Y: When the robotic
lawnmower is standing horizontally, the
value should be max ±3%. Inclination up and
to the left give negative values.
• Normal position: YES indicates that the
mower is standing in a normal position and
NO indicates that the mower is upside down.
The Info - Sensors - Temp display mode shows the
mower's temperature measured from a temperature
sensor on the control board and the temperature in
the display (LCD temp).
The Info - Automower Connect display mode shows
information on the Automower Connect accessory.
The following information, amongst other things, is
obtained:
• SIM card: Status of SIM card in Automower
Connect module.
Status Description
OK Connected
PIN SIM PIN required.
PUK SIM PUK required.
An incorrect PIN code has
been entered too many
times. The PUK code can
not be entered in the mower
menu but the SIM card must
be inserted into a cell phone
to be unlocked.
Locked The SIM card is locked.
An incorrect PUK code has
been entered too many
times. The SIM card has
been permanently locked and
must be replaced.
Error Other fault.
- Automower Connect not
active / No SIM card.
• GPRS-status:
Status Description
OK Connected Required on order
to communicate with the app.
“OK” is the only valid status
for communication with app.
Error Not connected, no GPRS
link. The mower can not
connect to a 2G base station,
e.g. if the mower is stored in
a basement.
Temp: 22.0°C
LCD temp: 20.4°C
Status Temp
COM: 6.00.00
SIM card: OK
GPRS: OK
Data: On
SMS On
RSSI OK
Automower Connect
2. SPECIAL MENU FUNCTIONS