HUST H2N Connection Manual
6 - 8
C130~C143 Reserved
C144~C145 To enable digital readout mode for X, Y-axis
C146~C159 Reserved
C160~C163 Hardware limit for (+/-) X, (+/-) Y-axis
C164~C191 Reserved
C192~C193 Clear error count to 0 for X, Y-axis
C194~207 Reserved
C208 X-axis. Positioning execution in PLC
C209 Y-axis. Positioning execution in PLC
C210~C223 Reserved
C224~C225 Set G28, G29, G30 mode
C226~C227 Reserved
C228
In JOG mode, axial movement control if R233 or R234 ≠ 0.
C229~C230 Feed-rate adjustment by MPG hand-wheel
C231
When C231=1→0, read the program that was stored in the EPROM/FLASH-ROM
C232 Reserved
C233
When C233=1→0, Clear G54 work coordinates (MCM #1~#2 = 0)
C234~C234 Reserved
C235 Program simulation without V-command output and encoder feedback
C236 For system use only
C237~C241 Reserved
C242 MPG hand-wheel feed (input) for INACTIVE axis during AUTO mode
C243 MMI (Man Machine Interface) or LCD screen in sleep mode
C244 Suppressing alarm ERROR-2 when following count > 4096
C245 User defined keyboard function input
C246 Reserved
C247 LCD display disabled
C248~C254 Reserved
C255 User defined keyboard function output