Maintenance
HPR130XD Auto Gas 806330 5-29
Plasma system operation with pump time-out
No
HPR
power supply
power-up
Error output
on
If 30 minutes has
passed since the
last start, turn OFF
thepump
Fire the torch
and begin
cutting
If the pump has timed out,
turnon the NOT READY
FORSTART signal and
turnon the pump
Purge cycle begins, NOT
READY FOR START
signal is active
System is in IDLE state
waitingfor a START signal,
NOTREADYFORSTART
signal is inactive
PLASMA START
signal active
STARsignal
Is the flow
sensorsatisfied?
Purge timer done
Yes
Yes
Yes
START signal
removed
No
No