EasyManua.ls Logo

Hypertherm HyPerformance HPR130XD

Hypertherm HyPerformance HPR130XD
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
InstallatIon
3-26 HPR130XD Auto Gas 806330
Examples of output circuits
1. Logic interface, active-high
2. Logic interface, active-low
3. Relay interface
4. Do not use this configuration. Warranty will be void.
High-impedance (≤10 mA)
10K
(optional)
CNC/PLC
5 VDC-24 VDC
C
HPR
E
+
-
HPR
C
E
+
-
5 VDC-24 VDC
High-impedance (≤10 mA)
CNC/PLC
10K
(optional)
CNC/PLC
CNC +24 V
+24 VDC
CNC +24 V
HPR
C
E
+
-
Power
ground
High-current
contact closure
inputs (AC or DC)
°t
Any voltage
VOIDS
WARRANTY
HPR
Install a
Jumper
108056
J304
C
E
+
-
External relay
24 VDC low-power coil
≤10 mA or ≥2400 ohms
All relay coils require a freewheeling diode
across the relay coil

Table of Contents