Appendix B – CnC interfACe protoCol
b-2 HPR130XD Auto Gas 806330 Revision 1
Interface hardware
• Theinterfacewilluseacombinationofdiscretesignals(5inputs,3outputs,and24VDCactivelow)andan
addressable RS422 interface.
• Thehardwarewillprovide4uniqueaddresses,whichallows4systemstobeconnectedtooneserialportonthe
CNC. The addressing mechanism will be inside the power supply, on a PC board (Note: A total of 32 I/O
(20 Inputs, 12 Outputs) points will be required for 4 systems).
• TheRS422hardwarewillhavetri-stateabletransmittertodisconnectitselffromthelinewhennot
communicating.
• MountingholesforfootprintofCommandTHCplasmainterfaceboard.
• MusthaveaninterfacecompatiblewiththeCommandTHC/HD4070.
Signal list
Signals
Signal name Type Description
Plasma Start Input When active, the plasma system will fire an arc.
Machine Motion 1 Output Indicates the arc has transferred to the plate. This signal is selected
using jumper on power supply control board. Only 1 motion signal
is needed per system. The remaining motion signals can be used to
wire multiple systems in a daisy chain configuration.
Machine Motion 2 Output Indicates the arc has transferred to the plate. This signal is selected
using jumper on power supply control board. Only 1 motion signal
is needed per system. The remaining motion signals can be used to
wire multiple systems in a daisy chain configuration.
Machine Motion 3 Output Indicates the arc has transferred to the plate. This signal is selected
using jumper on power supply control board. Only 1 motion signal
is needed per system. The remaining motion signals can be used to
wire multiple systems in a daisy chain configuration.
Machine Motion 4 Output Indicates the arc has transferred to the plate. This signal is selected
using jumper on power supply control board. Only 1 motion signal
is needed per system. The remaining motion signals can be used to
wire multiple systems in a daisy chain configuration.
Hold Ignition Input When active, the system will stay in preflow and delay torch ignition.
The signal should be applied at the same time the start signal is
applied.
System Error Output Indicates that an error has occurred in the plasma system. Use the
serial interface to query for the specific error code number.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance HPR130XD and is the answer not in the manual?

Hypertherm HyPerformance HPR130XD Specifications

General IconGeneral
BrandHypertherm
ModelHyPerformance HPR130XD
CategoryWelding System
LanguageEnglish

Related product manuals