InstallatIon
HPR130XD Auto Gas 806330 3-27
Examples of input circuits
Output from
CNC/PLC
External relay
(AC or DC)
1. Relay interface
+24 VDC
HPR
Power
ground
2. Optocoupler interface
CNC/PLC
+24 VDC
HPR
Power
ground
Transistor-output
optocoupler
12 V-24 VDC
CNC/PLC
+24 VDC
HPR
Power
ground Power
ground
Active-high drive
3. Amplified-output interface
Note: The external relay’s life may be improved by adding a
metallized-polyester capacitor (0.022µF 100 V or higher)
inparallel with the relay contacts.