InstallatIon
HPR130XD Auto Gas 806330 3-15
Placement of the selection console
• Mount the selection console near the cutting table. Allow room to remove the top and right side cover for
servicing. Preferred orientation is shown in the figure below. The maximum length of cables between the power
supply and selection console is 75 m (250 ft). The maximum length of cables and hoses between the selection
console and the metering console assembly is 20 m (65 ft).
Preferred selection
console orientation
Selection console grounding
314.5 m
12.38 inch
254.0 mm
10.0 inch
0
38.1 mm
1.5 inch
0
76.2 mm
3.0 inch
7 mm
0.28 inch
(4 places)
D