SOFTWARE FUNCTIONAL DESCRIPTION
b-4 HPR400XD Manual Gas Instruction Manual
10. Final ramp-down
Chopper setpoints = 0.
Error checking
Check for coolant flow at power-up (093).
11. Auto-off
Turn off pilot arc relay, pilot arc controller, HF, and machine motion outputs.
Preflow gases run for a 10-second postflow period.
If error has occurred, turn on CNC error output.
If Ramp-down error has occurred, turn on CNC Ramp-down error output.
Postflow timer and contactor timer run for 10 seconds.
If no Start signal, go to Idle2 state.
Error checking
Check for coolant flow at power-up (093).
12. Shut-down
Gas console goes to Shut-down state.
All outputs off.
CNC error output on.
Chopper setpoints = 0.
Wait for reset request.
13. Reset
Reset CAN controller.
• Initialize timers.
Go to Idle state.
14. Test cutflow
Gas console runs cutflow gases.
Wait for request to go to Idle state or Test Preflow state.
Error checking
Check for coolant flow at power-up (093).
Check for no Start signal.
15. Test preflow
Gas console runs preflow gases.
Wait for request to go to Idle state or Test Cutflow state.
Error checking
Check for coolant flow at power-up (093).
Check for no Start signal.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance HPR400XD and is the answer not in the manual?

Hypertherm HyPerformance HPR400XD Specifications

General IconGeneral
BrandHypertherm
ModelHyPerformance HPR400XD
CategoryCutter
LanguageEnglish

Related product manuals