© 2023 HyQuest Solutions 33
Configuration
Source
Description
Raw Range
Multipl
ier
Offset
0
Unused / disabled
N/A
N/A
N/A
1
Analogue Input 1
0 to 5000
2
Analogue Input 2
0 to 5000
3
Pulse Counter on Digital Input 1
0 to 1
4
Pulse Counter on Digital Input 2
0 to 1
5
Auto Pulse Counter on Digital Input 1
(Simulates a regular pulse every second
while DI1 is active).
0 to 1
6
Auto Pulse Counter on Digital Input 2
(Simulates a regular pulse every second
while DI2 is active).
0 to 1
7
Frequency Counter on Digital In 1
0 to 5000Hz
8
Frequency Counter on Digital In 2
0 to 5000Hz
9
Up/Down Counter on Digital Ins 1 & 2
10
Database Location
-32768 to
32767
11
Floating Point Database Location
12
SDI-12
13
Supply Voltage
0 - 1605
0.01
0
14
Temperature
0.1
0
15
Change of State 1
16
Change of State 2
17
Day to Now Total 1
18
Day to Now Total 2
19
Year to Date Total 1
20
Year to Date Total 2
Table 4 – Sensor Sources