User Menu
3-14 SlideSmart DC Installation and Reference Manual Revision D
9
5
0 through 9
Under some extreme high or low temperature conditions, it
may be necessary to adjust the contrast of the LCD display.
The display is adjustable from 0-9 with a factory default
setting of 5.
(N/A)
10
0 = off (standard)
1 = on (detailed)
Set this item to 1 to record all gate operator open and close
events, in addition to the normal alert, fault and error logs.
This parameter automatically resets to the default 0 (off)
after 24 hours, which is useful when experiencing
intermittent problems.
Set to 0, the DC Controller logs pertinent gate operator
events such as faults, errors, or menu manipulation.
USB or RS232 cable and
laptop computer with
HySecurity’s free START
software is required to read
the log file.
Tabl e Notes : The following conditions apply to the indicated reference-numbered menu selections: 2 & 3 For gate operators using Type D entrapment protection, an automatic closing
device (such as a timer, loop sensor, or similar device) shall not be employed. For additional information, refer to Choosing Secondary Entrapment Protection.
Note2: Force Open Alert (FA) and Drift Close Alert (DA) don’t appear in the User Menu because they are always active (ON) in SlideSmart DC. In SwingSmart DC, FA and DA
appear as menu items because you have the option to make them active or inactive (turn them ON or OFF).
Table 3-1. Smart DC Controller - User Menu Functions
Ref.
No.
*
User Menu
Setting Options
(
Bold = Factory Settings
) Menu Tasks and Explanations
Associated
DC Controller
Connections
Display
DS 0 (OFF)
DIAGNOSTIC LOGS