57
7) Remove the motor.
Remove the affixing bolts (M4 × 15, 4 pcs.) using an Allen wrench of 3mm across flats.
• Decoupled motor
Pull out the motor by hand.
8
)
Install a new motor.
After confirming that the angles of projections and depressions on the couplings are aligned, tighten the
affixing bolts (M4 × 15, 4 pcs.).
(Use an Allen wrench of 3mm across flats.)
Tightening torque: 176N·cm (18kgf·cm)