Host I/O
When troubleshooting disk drive and connectivity faults, stop I/O to the affected disk groups from all
hosts as a data protection precaution.
As an additional data protection precaution, it is helpful to conduct regularly scheduled backups of your
data. See also Stopping I/O.
Dealing with hardware faults
Ensure that you have obtained a replacement module of the same type before removing any faulty
module as described in Module removal and replacement.
Important: If the enclosure system is powered up and you remove any module, replace it immediately. If
the system is used with any modules missing for more than a few seconds, the enclosure(s) can overheat,
causing power failure and potential data loss. Such action can invalidate the product warranty.
Important: Observe applicable/conventional ESD precautions when handling modules and components,
as described in ESD precautions. Avoid contact with midplane components, module connectors, leads,
pins, and exposed circuitry.
Continuous operation during replacement
ESS software provides capability for replacing a failed disk without the loss of access to any le system on
the enclosure. Enclosure access and use during this period is uninterrupted. If an enclosure is equipped
with redundant PSUs, sufcient power is provided to the system while the faulty module is replaced.
Note: Model 106 enclosures support hot-plug replacement of redundant expansion enclosure canisters,
power supplies, fan modules, and HS expanders. Hot-add replacement of expansion enclosures is also
supported.
Firmware updates
After installing the hardware and powering on the storage system components for the rst time, verify
that the controller modules, expansion modules, and disk drives are using the current rmware release.
Periodically, you should ensure that the rmware versions used in enclosure modules are compatible.
Product Release Notes
®
describe the process for updating rmware. Contact your account manager for
additional information.
Procedure: Transporting an expansion enclosure
Safely transport an expansion enclosure by following this procedure.
See “Relocating ESS racked system 5147-106 (4U106)” on page 4 before you start transporting the
enclosure.
To transport an expansion enclosure between locations, or to transport an entire rack that contains one or
more of these enclosures, follow these steps to protect against drive damage.
1. Safely power down the enclosure by referring to “Powering on/powering off” on page 53. Do not
remove rack power until systems are safely powered down.
2. Transfer all of the drives in the enclosure into their original packaging or equivalent packaging for safe
transportation. For more information on removing the disk drive, see “Removing a LFF drive carrier
module” on page 76.
62
IBM ESS expansion: Hardware Installation and Maintenance Guide - Model 106

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 106 and is the answer not in the manual?

IBM 106 Specifications

General IconGeneral
BrandIBM
Model106
CategoryEnclosure
LanguageEnglish

Related product manuals