EasyManua.ls Logo

IBM Flex System p260 - Page 194

IBM Flex System p260
524 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B7006974
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7006978
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7006979
Explanation: Informational system log entry only.
Response: No corrective action is required.
B700697C
Explanation: Connection from service processor to system processor failed.
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006980
Explanation: RIO, HSL or 12X controller failure
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006981
Explanation: System bus error.
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006984
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7006985
Explanation: Remote I/O (RIO), high-speed link (HSL), or 12X loop status message.
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006974 B7006985
182 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide

Table of Contents

Related product manuals