B7006974
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7006978
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7006979
Explanation: Informational system log entry only.
Response: No corrective action is required.
B700697C
Explanation: Connection from service processor to system processor failed.
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006980
Explanation: RIO, HSL or 12X controller failure
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006981
Explanation: System bus error.
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006984
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7006985
Explanation: Remote I/O (RIO), high-speed link (HSL), or 12X loop status message.
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006974 • B7006985
182 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide