651-199
Explanation: This is a test of the flow of a serviceable event from this system to management console. This is not a
real problem.
Response:
Problem determination: Use the management console to list serviceable events and verify the serviceable event was
sent to the HMC.
652-600
Explanation: A non-critical error has been detected: uncorrectable memory or unsupported memory. Schedule
deferred maintenance. Examine the memory modules and determine if they are supported types. If the modules are
supported, then replace the appropriate memory modules.
Response:
652-610
Explanation: A non-critical error has been detected: CPU internal error. Schedule deferred maintenance. Go to
Performing the checkout procedure.
Response:
Failing Item:
v FFC_210
652-611
Explanation: A non-critical error has been detected: CPU internal cache or cache controller error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_210
652-612
Explanation: A non-critical error has been detected: external cache parity or multi-bit ECC error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_D01
651-199 652-612
310 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide

Table of Contents