652-613
Explanation: A non-critical error has been detected: external cache ECC single-bit error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_D01
652-623
Explanation: A non-critical error has been detected: correctable error threshold exceeded. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_2C6
652-630
Explanation: A non-critical error has been detected: I/O expansion bus parity error. Schedule deferred maintenance.
Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_307
652-631
Explanation: A non-critical error has been detected: I/O expansion bus time-out error. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_307
652-632
Explanation: A non-critical error has been detected: I/O expansion bus connection failure. Schedule deferred
maintenance. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_307
652-613 • 652-632
Chapter 8. Troubleshooting 311

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System p260 and is the answer not in the manual?

IBM Flex System p260 Specifications

General IconGeneral
BrandIBM
ModelFlex System p260
CategoryServer
LanguageEnglish

Related product manuals